Spectra UV-VIS-NIR Quasar Series Scientific Monochromators Print
Model : HO-SP-SQR500FA | HO-SP-SQR300FA | HO-SP-SQR500F | HO-SP-SQR300F

HOLMARC Spectra Quasar Series Monochromator Model : HO-SP-SQR500FA & HO-SP-SQR300FA are fully automated, triple grating instrument with dual output port and designed for fast, automated, continuous scanning over a broad spectral range. While Model : HOSP-SQR500F & HO-SP-SQR300F are single grating instrument. The angular position of the grating is adjusted by use of sine drive mechanism so that the required wavelength of light is passed through the exit slit and all other wavelengths are blocked. Positions of mirrors and slits are not changed.

Spectra Quasar series monochromators are ideal choice for either single or multichannel detector use in many applications that require medium to high spectroscopic resolution with excellent stray light performance such as fluorescence, Raman, absorption, transmission. Spectra series monochromators are fully automated with microprocessor controls . These can be operated either from the front panel of the instrument or through a personal computer which can be interfaced with the device by using RS 232C serial port. The instrument is made user friendly by incorporating LCD display and keyboards. Input and output ports of the monochromator are fitted with precise, micrometer controlled variable slits.

The software developed for the instrument has facilities for setting up and calibration as well. System accepts input data as wavelength or wave number. Various configurations of input and output ports are available all with high precision and long life time.

Precision stepper motor controlled rotation stage is used for driving the grating. Very fine resolution for the grating stage is achieved by the micro-stepping feature of the stepper motor control. Wavelength selection is made much easier with automated system compared to manually adjusted versions.

HO-SP-SQR300F HO-SP-SQR500F HO-SP-SQR300FA HO-SP-SQR500FA
    Spectra Quasar 300F Monochromator
    Model : HO-SP-SQR300F
    Optical Design : Czerny-Turner
    Input Port : Single
    Output Port : Single for monochromatic and light detection application
    Main Mirrors : Parabolic type with Enhanced Aluminum Coating
    Focal Length : 300 mm
    Diameter : 68 mm
    Aperture Ratio : f / 6 (with 50 x 50mm grating)
    Dispersion Element : Holographic Grating
    Grating Size : 50 x 50 mm
    Grating Density : 1200 l/mm
    Wavelength Range : 200 - 1600 nm
    Diffraction Efficiency @532nm : 65 %
    Dispersion : 2.29 nm / mm (52.13 cm-1 / mm)
    Resolution : 0.046 nm
   Mehanical Wavelength Range
   @1200 l/mm
: 200 - 1600 nm
    Accuracy : 0.01 nm (with 1200-g/mm grating)
    Reproducibility : ±0.005 nm (with 1200-g/mm grating)
    Grating Mounting Design : Single Grating
    Grating Rotation : Front Surface Axis
    Grating Holding Sizes : 50 x 50mm, 68 x 68mm (Grating adaptor will be provided)
    Grating Removal Port : Yes
    Output Port Size : 30 mm
    Focal Imaging Plane : 20 x 12 mm
    Focal plane extension from the port : 50 mm
    Slit Width Range : 0 - 3 mm
    Resolution : 1 Micron
    Filter unit : Higher order cut off filter wheel
    Software : Windows based software to control all
spectrometer functions and detector readings
(with Labview interface support)
▲ Top
    Spectra Quasar 500F Monochromator
    Model : HO-SP-SQR500F
    Optical Design : Czerny-Turner
    Input Port : Single
    Output Port : Single for monochromatic and light detection application
    Main Mirrors : Parabolic type with Enhanced Aluminum Coating
    Focal Length : 500 mm
    Diameter : 70 mm
    Aperture Ratio : f / 10 (with 50 x 50mm grating)
    Dispersion Element : Holographic Grating
    Grating Size : 50 x 50 mm (Elemental Array Design)
    Grating Density : 1200 l/mm
    Wavelength Range : 200 - 1600 nm
    Diffraction Efficiency @532nm : 65 %
    Dispersion : 1.426 nm / mm
    Resolution : 0.029 nm
   Mehanical Wavelength Range
   @1200 l/mm
: 200 - 1600 nm
    Accuracy : 0.01 nm (with 1200-g/mm grating)
    Reproducibility : ±0.005 nm (with 1200-g/mm grating)
    Grating Mounting Design : Single Grating
    Grating Rotation : Front Surface Axis
    Grating Holding Sizes : 50 x 50mm, 68 x 68mm (Grating adaptor will be provided)
    Grating Removal Port : Yes
    Output Port Size : 30 mm
    Focal Imaging Plane : 30 x 12 mm
    Focal plane extension from the port : 50 mm
    Slit Width Range : 0 - 3 mm
    Resolution : 1 Micron
    Filter unit : Higher order cut off filter wheel
    Software : Windows based software to control all
spectrometer functions and detector readings
(with Labview interface support)
▲ Top
    Spectra Quasar 300FA Monochromator
    Model : HO-SP-SQR300FA
    Spectra Quasar 300FA Fully Automated Monochromator
    Optical Design : Czerny-Turner
    Input Port : Single
    Output Port : Dual (One for monochromatic and other for light detection application)
    Port Selection Mechanism : Integrated Motorized Flip Mirror based Mechanism
    Main Mirrors : Parabolic type with Enhanced Aluminum Coating
    Focal Length : 300 mm
    Diameter : 100 mm
    Aperture Ratio : f / 3 (with 100 x 100mm grating)
    Dispersion Element : Holographic Grating
    Grating Size : 100 x 100mm (Elemental Array Design)
    Grating Density : 1200 l/mm
    Wavelength Range : 200 - 1600 nm
    Diffraction Efficiency @532nm : 65 %
    Dispersion : 2.29 nm / mm (52.13 cm-1 / mm)
    Resolution : 0.046 nm
   Mehanical Wavelength Range
   @1200 l/mm
: 200 - 1600 nm
    Accuracy : 0.05 nm (with 1200-g/mm grating)
    Reproducibility : ±0.001 nm (with 1200-g/mm grating)
    Grating Mounting Design : Triple Grating Turret Based (Can hold up to 3 Gratings)
    Mount Design : Kinematic Top Adjustable Mounts
    Grating Rotation : Front Surface Axis
    Grating Holding Sizes : 50 x 50mm, 68 x 68mm, 100 x 100mm
(Grating adaptor will be provided)
    Grating Removal Port : Yes
    Output Port Size : 20 mm
    Focal Imaging Plane : 20 x 12 mm
    Focal plane extension from the port : 30 mm
    Scanning Speed : 160 nm / second
    Step Size Resolution : 0.001 nm
    Input and Output Slit Design : Integrated Motorized Slit
    Slit Width Range : 0 - 3 mm
    Resolution : 1 Micron
    Shutter : Integrated motorized Active Shutter
    Filter unit : Higher order cut off filter wheel
    Calibration : Auto calibration for all motorized function
(Manual Calibration can be activated
for wavelength calibration)
    Software : Windows based software to control all
spectrometer functions and detector readings
(with Labview interface support)
▲ Top
    Spectra Quasar 500FA Monochromator
    Model : HO-SP-SQR500FA
    Spectra Quasar 500FA Fully Automated Monochromator
    Optical Design : Czerny-Turner
    Input Port : Single
    Output Port : Dual (One for monochromatic and other for light detection application)
    Port Selection Mechanism : Integrated Motorized Flip Mirror based Mechanism
    Main Mirrors : Parabolic type with Enhanced Aluminum Coating
    Focal Length : 500 mm
    Diameter : 120 mm
    Aperture Ratio : f / 5 (with 100 x 100mm grating)
    Dispersion Element : Holographic Grating
    Grating Size : 100 x 100mm (Elemental Array Design)
    Grating Density : 1200 l/mm
    Wavelength Range : 200 - 1600 nm
    Diffraction Efficiency @532nm : 65 %
    Dispersion : 1.426 nm / mm
    Resolution : 0.029 nm
   Mehanical Wavelength Range
   @1200 l/mm
: 200 - 1600 nm
    Accuracy : 0.01 nm (with 1200-g/mm grating)
    Reproducibility : ±0.005 nm (with 1200-g/mm grating)
    Grating Mounting Design : Triple Grating Turret Based (Can hold up to 3 Gratings)
    Mount Design : Kinematic Top Adjustable Mounts
    Grating Rotation : Front Surface Axis
    Grating Holding Sizes : 50 x 50mm, 68 x 68mm, 100 x 100mm
(Grating adaptor will be provided)
    Grating Removal Port : Yes
    Output Port Size : 30 mm
    Focal Imaging Plane : 30 x 12 mm
    Focal plane extension from the port : 50 mm
    Scanning Speed : 160 nm / second
    Step Size Resolution : 0.001 nm
    Input and Output Slit Design : Integrated Motorized Slit
    Slit Width Range : 0 - 3 mm
    Resolution : 1 Micron
    Shutter : Integrated motorized Active Shutter
    Filter unit : Higher order cut off filter wheel
    Calibration : Auto calibration for all motorized function
(Manual Calibration can be activated
for wavelength calibration)
    Software : Windows based software to control all
spectrometer functions and detector readings
(with Labview interface support)
▲ Top
Can be used as stitched or continuous scanning spectrometer.
Micrometer adjustable slits for precision control of incoming light.
User specified gratings to meet specific applications.
Stepping motor scanning for precision wavelength positioning.
Optional internal shutter or filter wheel.
Optional motorized slit.
Custom configurations.