This model of polarizer mount has spur gear drive with stepper motor. The polarizer mount is supported on ball bearing for smooth and noiseless positioning. Resolution and repeatability is around 0.5°. Maximum speed is limited to 36° per second. Holmarc provides control modules for these devices either with stand alone user interface or with PC control. Various adaptors are available for small size optics and prisms on request.
Note : Controller & Software sold separately.
Positioning accuracy : 0.5 degree |
Maximum speed : 160 degree / sec |
Minimum continues speed : 0.25 degree / sec |
Maximum optic size : 50mm / 2” |
Optic holding : by threaded ring |
Thread : HM-2 |
Adapters available as per request |
Free rotation dial with magnetic lock for stetting fast axis |
Optical limit switch for home sensing |
Hand wheel for manual movement |
Stepper motor for computer control movement |
Controller with software for computer controlling |
Additional handheld unit or joysticks available as per request |
Model No | Optic Size | Thread | Resolution | Speed | Price $ |
MPR-HSLR-25 | 25 mm / 1" | HM1 | 0.5 degrees | 160 degree / sec | 347.00 |
MPR-HSLR-50 | 50 mm / 2" | HM2 | - | - | 339.00 |
Single axis controller # Controller sold separately | 900.00 |
Controller details
A Windows software is supplied along with the controller which can be used for moving the rotator to the reference position (Home) and also to set different angular positions from the reference point.
Also, the low level command codes for controlling the rotator will be provided using which the user can develop his own software in his programming language of choice.
The PC interface is serial (RS232). A USB to serial converter will be supplied to connect the controller to a USB port, in case a serial port is not available.
Note : Controller & Software sold separately.
Instruction Set
Home : Moves the stage of the axis specified towards home.
Move [displacement] : Moves the stage for the specified displacement in Microns.
Wait : Incorporates a delay.
Speed : Set the speed in microns/second. One step is the resolution of the axis.
Trigger IN : The program waits for an external trigger which is a TTL pulse applied through the Trigger Input on the front panel of the controller.
Trigger OUT : The controller output a trigger which is a TTL pulse of 50 millisecond width.
Loop [index, address] : The program loops index times from the address specified.
Reset : Resets the position displays of the axis specified to zero.